Surge Phenomenon in Chiller Systems

Eng. Mohammed Salah Eldeen Babiker Mohammed | Updated: 09 July 2025

Abstract

The surge phenomenon in centrifugal chillers presents a critical operational risk with serious implications on system performance, maintenance costs, and equipment longevity. This paper explores the underlying causes of surge, its mechanical and economic impact, and proposes practical strategies for prediction, prevention, and control within HVAC systems.

1. Introduction

Chillers play an essential role in large-scale HVAC systems, providing critical thermal regulation in commercial, industrial, and institutional settings. Centrifugal compressors, widely used for their efficiency and capacity, are susceptible to a condition known as surge. Surge is a dynamic instability that can lead to mechanical failure, excessive vibration, and operational downtime. Understanding this phenomenon is vital for ensuring safe, efficient, and cost-effective chiller operation.

2. Surge Mechanism in Centrifugal Compressors

Surge occurs when the flow of refrigerant gas through a centrifugal compressor falls below the stable operating threshold, causing a rapid reversal of flow. This is typically due to an increase in discharge pressure or a drop in suction flow. The result is a repetitive cycle of flow breakdown and recovery known as a surge cycle, which creates damaging pressure pulsations and mechanical stress on the compressor.

3. Operational Causes of Surge

The following are the key causes of surge in chiller systems:


  1. Low refrigerant flow due to reduced load or throttled expansion valves
  2. Sudden drop in thermal load leading to low evaporator output
  3. Obstruction or fouling in the condenser or evaporator
  4. Poorly tuned Variable Frequency Drives (VFD) or low-speed compressor operation
  5. Operation outside the compressor's design map or surge curve
  6. Abrupt valve or control system changes causing flow instability

4. Consequences and Operational Risk

The consequences of surge are both mechanical and economic. From a mechanical standpoint, surge leads to excessive vibrations, damage to impellers, bearing wear, and potential failure of internal components. Operationally, it results in decreased system reliability, unexpected shutdowns, and increased frequency of maintenance.

5. Economic Impact of Surge

Surge significantly increases operating costs through unplanned maintenance, loss of efficiency, equipment replacement, and extended downtime. Estimates suggest that chronic surge conditions may reduce compressor lifespan by up to 50% and raise total operational costs by 15-30%. Energy consumption also rises as the system compensates for the irregular flow conditions.


6. Surge Mitigation Strategies

Recommended strategies to mitigate surge include:


  1. Install surge detection and protection systems with automatic shutdown or bypass
  2. Use bypass lines to stabilize pressure during low flow events
  3. Maintain operation within manufacturer-specified compressor maps
  4. Implement predictive controls using real-time flow and pressure sensors
  5. Schedule routine inspections and cleaning of condenser and evaporator coils
  6. Train operators to recognize surge warning signs and react promptly

7. Conclusion

The surge phenomenon in chiller systems is a serious concern that necessitates proactive design, monitoring, and control. By understanding the mechanisms, root causes, and preventive measures, facility managers and engineers can ensure system longevity, reduce operational costs, and maintain optimal performance. Surge management is not merely a technical issue but a strategic one that directly affects reliability and profitability in HVAC infrastructure.

Share this article